AAkar Architects

AAkar Architects Architectural Design and Consultancy. Innovative design and solutions.

its new start new beginning at nanoli
23/03/2020

its new start new beginning at nanoli

Prime residential bungalow for Mr. Jadhav at Jehe. Thank you sir for giving us opportunity to play with spaces and give ...
07/08/2019

Prime residential bungalow for Mr. Jadhav at Jehe. Thank you sir for giving us opportunity to play with spaces and give freedom to work.

Rock garden Chandigarh fabulous example use of stone in design proper sence of design contrast colour combination.... to...
09/06/2018

Rock garden Chandigarh fabulous example use of stone in design proper sence of design contrast colour combination.... totally fan of Mr. Nek Chand...

Use of west material Mr. Nek Chands fan
09/06/2018

Use of west material Mr. Nek Chands fan

Marriage hall project for Mr. Archana Deshmukh
10/08/2017

Marriage hall project for Mr. Archana Deshmukh

12/04/2017
23/03/2017

ผนังฉนวนธรรมชาติ

23/03/2017

กันแดดไม่กันแสง

Smart way of energy saving.
23/03/2017

Smart way of energy saving.

telivision ideal destance from viewer.
13/11/2016

telivision ideal destance from viewer.

11/11/2016

Three thumb rules to be followed are as follows:
Size of the Columns
Distance between Columns
Alignment of columns
Minimum Size of RCC columns
The size of the columns depends on the total load on the columns. There are axial loads and lateral loads. Large beam spans induce bending moment not only in the beams, but also in columns which are pulled by the stresses in the beams. It is important to use advanced structural design software like ETabs or Staad pro. I highly recommend every structural designer learn these software. The thumb rules are for general designing in very small projects.

For this general thumb rule, we will assume a structure of G+1 floors high, using standard 6″ walls.

Minimum size of an RCC column should not be less than 9”x 9” (225mm x 225mm) with 4 bars of 12 MM Fe500 Steel.

These days the minimum I use in my projects is 9″ x 12″ (225 mm x 300mm) with 6 bars of 12 MM Fe500 steel. You can never go wrong with strong columns. I also recommend use of M20 grade concrete for the structure (ratio 1 part Cement : 1.5 parts Sand : 3 parts Aggregate with 0.5 parts water by volume). I recommend use of 8 MM stirrups at a distance of 150 MM center to center throughout the length of column.

This setup of 9″ x 12″ RCC columns is safe for G+1 Floors. There are a lot of other considerations, but this is just a thumb rule.

Span (distance) between two columns
For the above column setup, a span of up to 5 meters is quite safe. One can use beams of size 9″ X 12″ (225 MM x 300MM) with a slab thickness of 5″ (125 MM) cast in M20 concrete for spans up to 5m. There are other considerations like secondary and tertiary spans, point loads and wall loads which have to be considered. It is complicated, but thumb rules can work if the structure is simple. It is always recommended to use structural design software like ETabs or Staad pro for design.

In a beam of up to 5 meters length, secondary spans of up to 4 meters, wall loads of up to 8 kN per running meter, I can use steel as below.

Top Steel – 2 bars of 12 MM
Crank bars – 2 bars of 12 MM, cranked at an angle of 45° at a distance of L/4 at both ends of a simply supported beam
Bottom Steel – 3 bars of 12 MM.
This configuration can change depending on a lot of factors.

Alignment of Columns
Placing of columns depend completely on the plan. A planner has a very important job. A grid column placement is always preferred in order to reduce point loads and unnecessary complications while construction. This reduces the cost of construction as well as time required for construction. Beams which have continuity with other simply supported beams have reduced bending moments, and thus require less steel and concrete depth to be safe.

Columns have to be connected with each other for smooth transfer of loads. An experienced planner will keep such things in mind when planning the structure.

Address

27, Sainand Baravkar Nagar MIDC
Satara
415004

Opening Hours

Monday 8am - 10am
7pm - 10pm
Tuesday 8am - 10am
7pm - 10pm
Wednesday 8am - 10am
7pm - 10pm
Thursday 9am - 5pm
Friday 9am - 5pm
Saturday 9am - 5pm
Sunday 9am - 10pm

Telephone

+919762427642

Website

Alerts

Be the first to know and let us send you an email when AAkar Architects posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share